The Drincable cable is suitable for permanent immersion in potable water to a depth of 600m. WRAS approved, it will not support microbial growth, or affect the taste, appearance, transparency or colour of water. It will not introduce metals or toxic substances. Designed for submersible pumps for drinking water, depuration and chlorination systems, electrical installations in manufacturing, processing and preserving systems of drinks and foodstuff, swimming pool lightings, and other water treatment operations. Available as a circular or flat configuration.
Flat Cables
STANDARDS
BE EN/IEC 60228, BE EN 50363-1, VDE 0207 part 20,
BS EN 50363-2-1,
ACS – WRAS approved
Acid and Alkaline Solution according to BE EN/IEC 60811-100 Ozone Resistant according to BS EN/IEC 60811-403
AD8 Water Resistance Test according to EN 50525-2-21 and
Building wire is used in the construction of almost every commercial, industrial, and residential property in the world. Most commonly known as branch circuit wiring in homes and businesses, these products carry electrical current to all external uses of power in a building or dwelling.
Building Wire LSF (BS 50525-3-41)
Electric Way supplies a comprehensive range of Low Smoke Zero Halogen Building wires manufactured in accordance with a number of British, European and international standards.
CONSTRUCTION
CONDUCTORS:
It is the current carrying component of the cable.
Material
Stranded plain annealed copper single core conductors
INSULATION
The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation
Material
450/750V with XL- LSZH Sheathing Compound.
CHARACTERISTICS
Voltage Rating:
450/750 Volts
Temperature Rating
-15°C to +90°C
Minimum Bending Radius
As per cable manufacturer datasheet
STANDARDS
BS EN 50525-3-41:
For LSZH Insulated Wiring
BS EN/IEC 60332-1-2:
For Flame Retardant
BS7211
Old standard, currently withdrawn or superseded
CORE IDENTIFICATION
1 core:
Red, Black, Yellow, Blue, Green/Yellow. (Other Color as per specified standard can also be manufactured)
APPLICATION: Most suited for use in conduit and for fixed protection installation. Can be used in lighting installations, switch and control gear and also in appliances. The Low Smoke Zero Halogen outer sheath is ideal in applications where fire, smoke, emissions and toxic fumes would create a potential threat.
Electric Way is a leading steel Wire Armoured and Aluminium wire armoured cable supplier offering a comprehensive range of robust and hard-wearing Low Voltage armoured and Medium Voltage armoured cables manufactured in accordance with British, European and International standards and specifications.
Armoured Cables PVC SheathedPVC and Lead Sheathed
CONSTRUCTION OF THE CABLE
Typically, the construction of an Aluminium or steel wire armoured cable comprises of the following components:
CONDUCTORS:
Current carrying component of the cable.
Material
Plain, stranded, compacted copper as per IEC: 60228 Aluminium, stranded, compacted conductors
INSULATION:
The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation.
Material
Cross-linked polyethylene (XLPE) Type GP8 as per BS 7655.
FILLERS:
For providing circular shape to the cable, non-hygroscopic compatible fillers (wherever necessary) are included between laid up cores.
BEDDING:
Extruded bedding serves as a bedding for the armour and as a protection for the laid-up cores.
Material
Extruded PVC Type 9 Compound as per BS 7655. Reduced propagation flame retardant (RPLHCL)/R PPVC Compound for reduced flame propagation characteristics.
ARMOUR:
Armour provides mechanical protection to the cable. It also serves as an Earth Continuity Conductor (ECC). One layer of round wire is applied helically over the bedding.
Material
1. Galvanised round steel wire (GSWA) – FOR MULTICORE CABLE 2. Aluminium round wire armour (AWA) – FOR SINGLE CORE.
OVERSHEATH – FINISH:
General Purpose: Extruded PVC Type 9 Compound as per BS 7655 and also meet fire test requirement of IEC 60332-1.
Material:
1. Medium Density Polyethylene (MDPE): Offers higher protection from water ingress and mechanical abrasion. 2. Anti-Termite: Termite resistance can be built in both types described above by compounding with proper additives. 3. Reduced Propagation (RP): Retards propagation of flame in fire situation. (Oxygen Index ≈ 30) 4. Reduced Propagation and Low Acid Fumes (RPLHCL): Retards propagation of flames and gives low emission of hydrochloric acid fumes. (OI ≈ 30 & acid gas emission is less than 18%)
CHARACTERISTICS
Voltage Rating:
Uo/U= 0.6/1kV
Temperature Rating:
Fixed: -25°C to +90°C
Minimum Bending Radius:
1.5mm2 to 16mm2 – Fixed: 6 x overall diameter 25mm2 and above – Fixed: 8 x overall diameter
STANDARDS
BS 5467:
for XLPE insulated armoured cables
BS 7889:
for XLPE insulated single core unarmoured cables
IEC 60502-1:
for XLPE insulated single/multicore armoured/unarmoured cables
IEC 60228/BS6360:
for copper conductor
BS 7655:
for Insulation, bedding and outersheath
IEC 60332:
for Flame propagation
CORE IDENTIFICATION
1 core:
Red, Black
2 core:
Red, Black
3 core:
Red, Yellow, Blue
4 core:
Red, Yellow, Blue, Black
5 core:
Red, Yellow, Blue, Black, Yellow/ Green
APPLICATION: Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary fixed wiring cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Flexible Cable products are designed and manufactured complying with the most recent international standards including BS 6004, BS 6500, BS 7919, IEC 60227.
Electric Way supplies comprehensive range PVC Flexible Cable.
Flexible Cable
Flexible Cable
CONSTRUCTION
The conductor is made of plain annealed high purity Class 5 Copper, having excellent specific electrical conductivity, and superior mechanical flexibility thanks to DuFlex conductor construction.
Polyvinyl Chloride (PVC) is used for insulating and sheathing material as it is suitable for various flexible applications like high electrical, mechanical and thermal properties.
CONSTRUCTION OF THE CABLE
It is the current carrying component of the cable.
CONDUCTORS:
Current carrying component of the cable.
Material
Flexible class 5 copper conductors to BSEN 60228.
INSULATION:
The act of separating a body from others by nonconductors, so as to prevent the transfer of electricity or of heat; also, the state of a body so separated.
Material
PVC Type TI 2 to BSEN 50363-3.
SHEATHING:
Protective casing or covering.
Material
PVC Type TM 2 to BSEN 50363-4-1.
CHARACTERISTICS
Voltage Rating:
300/500 V
Temperature Rating:
PVC Insulation suitbale for continuous operating temp. upto 70deg.C PVC Insulation Heat Resistance suitbale for continuous operating temp. upto 105deg.C
Minimum Bending Radius:
4 x Cable Diameter
STANDARDS
BS 6500:
for sizes upto 2.5mm2
BS 7919:
for sizes upto 4mm2
BSEN 60228:
Flexible class 5 copper conductors
BSEN 50363-3:
Insulation PVC Type TI 2
BSEN 50363-4-1:
Sheathing PVC Type TM 2
CORE IDENTIFICATION
2 CORE:
Blue and Brown
3 CORE:
Green/Yellow, Blue and Brown
4 CORE:
Green/Yellow, Blue, Brown and Black or Green/Yellow, Brown, Black and Grey
5 CORE:
Green/Yellow, Blue, Brown, Black and Grey
APPLICATION: For use in offices and household appliances such as computers, spin extractors, washing machines, spin dryers and refrigerators and also for all kinds of outdoor industrial use.
Building wire and cable is used in the construction of almost every commercial, industrial, and residential property in the world. Most commonly known as branch circuit wiring in homes and businesses, these products carry electrical current to all external uses of power in a building or dwelling.
Building Wire (BS 50525-2-31)
Electric Way supplies a comprehensive range of Building wires manufactured in accordance with a number of British, European and international standards.
CONSTRUCTION
CONDUCTORS:
It is the current carrying component of the cable.
Material
Stranded, high conductivity plain annealed copper wires as per class 2 in BS 60228 and IEC 60228 Aluminium, stranded, compacted conductors
INSULATION
The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation
Material
The insulation of standard wiring cables is PVC grade Type TI 1 of BS 7655 (formerly BS 6746) suitable for a maximum continuous conductor operating temperature of 70˚C.
CHARACTERISTICS
Voltage Rating:
450/750 Volts
Temperature Rating
-5°C to +70°C
Minimum Bending Radius
Fixed: 6 x overall diameter
STANDARDS
BS EN 50525-2-31:
For PVC Insulated Wiring
BS EN 60228
For conductor
BS 7655
For Insulation
BS EN/IEC 60332-1
For Flame Retardant
CORE IDENTIFICATION
1 core:
Red, Black, Yellow, Blue, Green/Yellow. (Other Color as per specified standard can also be manufactured)