Bare Copper
Bare Copper are Stranded Soft Annealed Copper Wire that is ideal for grounding electrical systems & equipment, or transmission and distribution in electrical networks.

Bare Copper are Stranded Soft Annealed Copper Wire that is ideal for grounding electrical systems & equipment, or transmission and distribution in electrical networks.





Earth Rod Accessories available with natural brass finish.
A copper Tape Accessory that is used to join two or more Copper Tapes together.


Some of the Copper Tape accessories are
| Earth Tape Junction Square: | The earth tape square is designed as a junction for Copper tape. This can be used as a straight through, 3-way tee or 4-way junction. The base is fixed by one centre countersunk hole and the top then secures the Copper tape by means of four screws. |
| Earth Tape Junction Clamp: | The oblong junction clamp is designed to join Copper tape together in a straight position. Tape should be overlapped and secured by the two bolts. |
| Metallic earth tape clips: | Metallic earth tape clips are designed to secure bare tape to the building surface by the means of one centre countersunk hole and two fixing screws. |
High conductivity copper tape is used on both lightning protection and earthing applications. It is annealed for ease of use and has radiuses edges.



Copper tape has countless applications in electronics from creating low-profile traces for electrical components to RF-shielding and antenna-making. Copper tape is even used to join things together using solder, like the stained glass on Tiffany lamps. It comes in two forms; conductive adhesive and non-conductive adhesive.
Designed for use on earthing circuits within the ship wiring and marine industry 657 SW4 earthing cables are manufactured to BS 6883 and are double insulated for electrical safety.



The outer sheath is colored green/yellow for identification.
| CONDUCTORS: | It is the current carrying component of the cable. |
| Material | Stranded, high conductivity plain annealed copper wires as per class 2 in BS 60228 and IEC 60228 Aluminium, stranded, compacted conductors |
| INSULATION | The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation |
| Material | The insulation of standard wiring cables is PVC grade Type TI 1 of BS 7655 (formerly BS 6746) suitable for a maximum continuous conductor operating temperature of 70˚C. |
| Voltage Rating: | 450/750 Volts |
| Temperature Rating | -5°C to +70°C |
| Minimum Bending Radius | Fixed: 6 x overall diameter |
| BS EN 50525-2-31: | For PVC Insulated Wiring |
| BS EN 60228 | For conductor |
| BS 7655 | For Insulation |
| BS EN/IEC 60332-1 | For Flame Retardant |
| 1 core: | Red, Black, Yellow, Blue, Green/Yellow. (Other Color as per specified standard can also be manufactured) |
APPLICATION:
Domestic wiring cable. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where the risk of mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.
The Drincable cable is suitable for permanent immersion in potable water to a depth of 600m. WRAS approved, it will not support microbial growth, or affect the taste, appearance, transparency or colour of water. It will not introduce metals or toxic substances. Designed for submersible pumps for drinking water, depuration and chlorination systems, electrical installations in manufacturing, processing and preserving systems of drinks and foodstuff, swimming pool lightings, and other water treatment operations. Available as a circular or flat configuration.

Building wire is used in the construction of almost every commercial, industrial, and residential property in the world. Most commonly known as branch circuit wiring in homes and businesses, these products carry electrical current to all external uses of power in a building or dwelling.

Electric Way supplies a comprehensive range of Low Smoke Zero Halogen Building wires manufactured in accordance with a number of British, European and international standards.
| CONDUCTORS: | It is the current carrying component of the cable. |
| Material | Stranded plain annealed copper single core conductors |
| INSULATION | The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation |
| Material | 450/750V with XL- LSZH Sheathing Compound. |
| Voltage Rating: | 450/750 Volts |
| Temperature Rating | -15°C to +90°C |
| Minimum Bending Radius | As per cable manufacturer datasheet |
| BS EN 50525-3-41: | For LSZH Insulated Wiring |
| BS EN/IEC 60332-1-2: | For Flame Retardant |
| BS7211 | Old standard, currently withdrawn or superseded |
| 1 core: | Red, Black, Yellow, Blue, Green/Yellow. (Other Color as per specified standard can also be manufactured) |
APPLICATION:
Most suited for use in conduit and for fixed protection installation. Can be used in lighting installations, switch and control gear and also in appliances. The Low Smoke Zero Halogen outer sheath is ideal in applications where fire, smoke, emissions and toxic fumes would create a potential threat.
Electric Way is a leading steel Wire Armoured and Aluminium wire armoured cable supplier offering a comprehensive range of robust and hard-wearing Low Voltage armoured and Medium Voltage armoured cables manufactured in accordance with British, European and International standards and specifications.


Typically, the construction of an Aluminium or steel wire armoured cable comprises of the following components:
| CONDUCTORS: | Current carrying component of the cable. |
| Material | Plain, stranded, compacted copper as per IEC: 60228 Aluminium, stranded, compacted conductors |
| INSULATION: | The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation. |
| Material | Cross-linked polyethylene (XLPE) Type GP8 as per BS 7655. |
| FILLERS: | For providing circular shape to the cable, non-hygroscopic compatible fillers (wherever necessary) are included between laid up cores. |
| BEDDING: | Extruded bedding serves as a bedding for the armour and as a protection for the laid-up cores. |
| Material | Extruded PVC Type 9 Compound as per BS 7655. Reduced propagation flame retardant (RPLHCL)/R PPVC Compound for reduced flame propagation characteristics. |
| ARMOUR: | Armour provides mechanical protection to the cable. It also serves as an Earth Continuity Conductor (ECC). One layer of round wire is applied helically over the bedding. |
| Material | 1. Galvanised round steel wire (GSWA) – FOR MULTICORE CABLE 2. Aluminium round wire armour (AWA) – FOR SINGLE CORE. |
| OVERSHEATH – FINISH: | General Purpose: Extruded PVC Type 9 Compound as per BS 7655 and also meet fire test requirement of IEC 60332-1. |
| Material: | 1. Medium Density Polyethylene (MDPE): Offers higher protection from water ingress and mechanical abrasion. 2. Anti-Termite: Termite resistance can be built in both types described above by compounding with proper additives. 3. Reduced Propagation (RP): Retards propagation of flame in fire situation. (Oxygen Index ≈ 30) 4. Reduced Propagation and Low Acid Fumes (RPLHCL): Retards propagation of flames and gives low emission of hydrochloric acid fumes. (OI ≈ 30 & acid gas emission is less than 18%) |
| Voltage Rating: | Uo/U= 0.6/1kV |
| Temperature Rating: | Fixed: -25°C to +90°C |
| Minimum Bending Radius: | 1.5mm2 to 16mm2 – Fixed: 6 x overall diameter 25mm2 and above – Fixed: 8 x overall diameter |
| BS 5467: | for XLPE insulated armoured cables |
| BS 7889: | for XLPE insulated single core unarmoured cables |
| IEC 60502-1: | for XLPE insulated single/multicore armoured/unarmoured cables |
| IEC 60228/BS6360: | for copper conductor |
| BS 7655: | for Insulation, bedding and outersheath |
| IEC 60332: | for Flame propagation |
| 1 core: | Red, Black |
| 2 core: | Red, Black |
| 3 core: | Red, Yellow, Blue |
| 4 core: | Red, Yellow, Blue, Black |
| 5 core: | Red, Yellow, Blue, Black, Yellow/ Green |
APPLICATION: Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary fixed wiring cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting.
Electric Way supplies comprehensive range PVC Flexible Cable.


The conductor is made of plain annealed high purity Class 5 Copper, having excellent specific electrical conductivity, and superior mechanical flexibility thanks to DuFlex conductor construction.
Polyvinyl Chloride (PVC) is used for insulating and sheathing material as it is suitable for various flexible applications like high electrical, mechanical and thermal properties.
It is the current carrying component of the cable.
| CONDUCTORS: | Current carrying component of the cable. |
| Material | Flexible class 5 copper conductors to BSEN 60228. |
| INSULATION: | The act of separating a body from others by nonconductors, so as to prevent the transfer of electricity or of heat; also, the state of a body so separated. |
| Material | PVC Type TI 2 to BSEN 50363-3. |
| SHEATHING: | Protective casing or covering. |
| Material | PVC Type TM 2 to BSEN 50363-4-1. |
| Voltage Rating: | 300/500 V |
| Temperature Rating: | PVC Insulation suitbale for continuous operating temp. upto 70deg.C PVC Insulation Heat Resistance suitbale for continuous operating temp. upto 105deg.C |
| Minimum Bending Radius: | 4 x Cable Diameter |
| BS 6500: | for sizes upto 2.5mm2 |
| BS 7919: | for sizes upto 4mm2 |
| BSEN 60228: | Flexible class 5 copper conductors |
| BSEN 50363-3: | Insulation PVC Type TI 2 |
| BSEN 50363-4-1: | Sheathing PVC Type TM 2 |
| 2 CORE: | Blue and Brown |
| 3 CORE: | Green/Yellow, Blue and Brown |
| 4 CORE: | Green/Yellow, Blue, Brown and Black or Green/Yellow, Brown, Black and Grey |
| 5 CORE: | Green/Yellow, Blue, Brown, Black and Grey |
APPLICATION: For use in offices and household appliances such as computers, spin extractors, washing machines, spin dryers and refrigerators and also for all kinds of outdoor industrial use.
Building wire and cable is used in the construction of almost every commercial, industrial, and residential property in the world. Most commonly known as branch circuit wiring in homes and businesses, these products carry electrical current to all external uses of power in a building or dwelling.

Electric Way supplies a comprehensive range of Building wires manufactured in accordance with a number of British, European and international standards.
| CONDUCTORS: | It is the current carrying component of the cable. |
| Material | Stranded, high conductivity plain annealed copper wires as per class 2 in BS 60228 and IEC 60228 Aluminium, stranded, compacted conductors |
| INSULATION | The rated voltage level of the cable depends on the dielectric strength and thickness of the insulation |
| Material | The insulation of standard wiring cables is PVC grade Type TI 1 of BS 7655 (formerly BS 6746) suitable for a maximum continuous conductor operating temperature of 70˚C. |
| Voltage Rating: | 450/750 Volts |
| Temperature Rating | -5°C to +70°C |
| Minimum Bending Radius | Fixed: 6 x overall diameter |
| BS EN 50525-2-31: | For PVC Insulated Wiring |
| BS EN 60228 | For conductor |
| BS 7655 | For Insulation |
| BS EN/IEC 60332-1 | For Flame Retardant |
| 1 core: | Red, Black, Yellow, Blue, Green/Yellow. (Other Color as per specified standard can also be manufactured) |
APPLICATION: